Disclaimer: This information is provided as is. There may be errors in this information. You may use this information only if you agree that Minimalist / Coinop.org, its employees, and noted authors will never be held responsible for any damage, injury, death, mayhem, etc. caused by errors in the information. When working with high voltage, never work alone and always follow safety precautions.

Document Title: [Sprint_1.txt (text file)]

Sprint One, Atari (1978):

44-pin edge connector
----------------------------------------------------
     VIDEO GND      | 1  | A  |    GND
     16.5v CT       | 2  | B  |    16.5v CT
     16.5v AC       | 3  | C  |    16.5v AC
     16.5v AC       | 4  | D  |    16.5v AC
     +10v UNREG     | 5  | E  |    +5v UNREG
     VIDEO          | 6  | F  |    STEERING 1A
     STEERING 1B    | 7  | H  |    COIN 2 N.O
     N/C            | 8  | J  |    COIN 1 N.O
     N/C            | 9  | K  |    PLAYER START LED
     SWITCH GND     | 10 | L  |    GAS PEDAL
     3rd GEAR       | 11 | M  |    2nd GEAR
     1st GEAR       | 12 | N  |    TEST
     START          | 13 | P  |    N/C
     N/C            | 14 | R  |    N/C
     N/C            | 15 | S  |    COIN COUNTER
     N/C            | 16 | T  |    N/C
     N/C            | 17 | U  |    N/C
     N/C            | 18 | V  |    N/C
     25v AC         | 19 | W  |    25v AC
     25v AC         | 20 | X  |    25v AC
     AUDIO          | 21 | Y  |    N/C
     25v CT         | 22 | Z  |    AUDIO GND



1 on  =   oil slicks
  off =   no oil slicks

2 on  =   cycle to next track every lap
  off =   cycle to next track every 2 laps

3,4
  on,on   1 coin/player
  on,off  2 players/coin
  off,on  2 coins /player
  off,off free play (no attract mode)

5 on =    extened play equalling 3/10 of game time (set by 7,8)
          if player obtains Pro rating during normal play
  off =   no extended play

6 not used

7,8
  on,on   game time 150 seconds
  on,off  game time 120 seconds
  off,on  game time 90 seconds
  off,off game time 60 seconds




}