Disclaimer: This information is provided as is. There may be errors in this information. You may use this information only if you agree that Minimalist / Coinop.org, its employees, and noted authors will never be held responsible for any damage, injury, death, mayhem, etc. caused by errors in the information. When working with high voltage, never work alone and always follow safety precautions.

Document Title: [UniWars.txt (text file)]

UNIWARS       
Irem 1980

 COMP SIDE                         CKT SIDE
----------                        ----------
  1  GND                              2  GND
  3  GND                              4  GND
  5  -5V                              6  -5V
  7  COIN                             8  1 PLYR VR
  9  1 LEFT                          10  2 LEFT
 11  1 RIGHT                         12  2 RIGHT
 13  1 FIRE                          14  2 FIRE
 15  1 START                         16  2 START
 17  VSYNC                           18  SYNC
 19                                  20  HSYNC
 21  +12V                            22  +12V
 23  +12V                            24  +12V
 25  SP-                             26  SP+
 27                                  28
 29  VID GRN                         30  VID RED
 31  VID BLU                         32  1 PLYR VR
 33                                  34  RESET
 35                                  36
 37  SERVICE SW                      38  COIN
 39  +5V                             40  +5V
 41  +5V                             42  +5V
 43  GND                             44  GND 






                                                 ON     TABLE

                                                 OFF    UPRIGHT


























































}